Product Name
AOD-9604
Product Name
ARA-290
Product Name
BPC-157
Product Name
BPC-157 / TB-500 / KPV Blend
Product Name
BPC-157 / TB-500 Blend
Product Name
Cagrilintide
Product Name
CJC-1295 / Ipamorelin Blend
Product Name
CJC-1295 No DAC
Product Name
CJC-1295 w/ DAC
Product Name
Diluent Solution
Product Name
DSIP
Product Name
DSIP Nasal Spray
Product Name
Epithalon
Product Name
GHK-Cu
Product Name
GHRP-2
Product Name
GHRP-6
Product Name
Glow + KPV Blend
Product Name
Glow Blend
Product Name
GLP-1
Product Name
GLP-2
Product Name
GLP-3
Product Name
Glutathione
Product Name
Gonadorelin
Product Name
IGF-1 LR3 (Receptor Grade)
Product Name
Ipamorelin
Product Name
Kisspeptin-10
Product Name
KPV
Product Name
LL-37
Product Name
Melanotan I
Product Name
Melanotan II
Product Name
Melanotan II Spray
Product Name
MOTS-c
Product Name
NAD+
Product Name
Oxytocin
Product Name
Oxytocin Spray
Product Name
Pinealon
Product Name
PT-141
Product Name
Selank
Product Name
Selank Spray
Product Name
Semax
Product Name
Semax / Selank Blend
Product Name
Semax + Selank Spray
Product Name
Semax Spray
Product Name
Sermorelin
Product Name
SS-31
Product Name
Tesamorelin
Product Name
Tesamorelin / Ipamorelin Blend
Product Name
Thymalin
Product Name
Thymosin Alpha-1 (Ta1)
Product Name
Thymosin Beta-4 (TB-4/TB-500)

Purity (HPLC)

Passed

Assessed via reverse-phase High-Performance Liquid Chromatography (HPLC) with UV detection to quantify the target compound and detect impurities. High purity reduces the presence of unintended constituents that may affect analytical outcomes.

Identity (USP <621>)

Passed

Confirms the molecular identity of the compound by chromatographic comparison against qualified reference standards per USP <621>. Identity verification is foundational to ensure the material being analyzed is correct and properly characterized.

Net Content (USP <41>)

Passed

Verifies that each vial meets its labeled quantity within acceptable variance, measured gravimetrically on a calibrated analytical balance per USP <41>. Accurate net content supports consistency across batches and reliability in downstream applications.

Multi-Vial Variance (USP <905>)

Passed

Multiple vials from the same lot are tested individually for purity, identity, and net content to confirm uniformity across the batch, following the uniformity of dosage units principles of USP <905>. This helps ensure consistent composition and performance vial to vial.

Endotoxins (USP <85>)

Passed

Measures bacterial endotoxin levels using validated LAL methods per USP <85>. Endotoxin control is critical for minimizing biological interference and maintaining integrity in sensitive analytical systems.

Microbial (USP <61>/<62>)

Passed

Assesses total aerobic and yeast/mold counts per USP <61> and screens for specified organisms per USP <62> to confirm compliance with microbiological quality standards. This helps ensure controlled, clean finished material.

Heavy Metals (ICP-MS, USP <233>)

Passed

Screens for elemental impurities such as lead, arsenic, cadmium, and mercury by ICP-MS per USP <233>, against the elemental impurity limits of USP <232>. Monitoring trace metals supports material purity and overall quality assurance.

Residual Solvents (USP <467>)

Passed

Screens for trace solvents left behind by synthesis, purification, and drying — such as acetonitrile, methanol, dichloromethane, ethanol, ethyl acetate, and other Class 1, 2, and 3 solvents. These are tested because residual solvents carry toxicity and impurity risk at low levels, so each lot is confirmed to sit within USP <467> safety limits.

Adulterant Testing (USP <2251>)

Passed

Screened per USP <2251> (Screening for Undeclared Drugs and Drug Analogues) for undeclared drugs and drug analogues, confirming the material is free of illicit contaminants.